BCIN-qualified septic design for Ottawa & Eastern Ontario
Davis Patel, C.E.T.
(613) 400-4536
info@ddsgroup.ca
A septic system is an on-site wastewater treatment system, usually a septic tank and a soil absorption area (leaching bed). The tank separates solids, and the bed lets the soil naturally filter and treat the effluent before it reaches groundwater.
Most residential installations cost between $20,000 and $50,000. Conventional systems typically run $20,000 to $45,000, while tertiary systems range from $35,000 to $90,000 plus annual servicing. Home size, bedrooms and fixtures, soil conditions and system type drive the price. Commercial costs depend on the size of the project.
Yes. Every new system, replacement or major repair needs a permit under the Ontario Building Code. In the City of Ottawa, permits are issued by the Rideau Valley Conservation Authority through the Ottawa Septic System Office (OSSO).
Depending on your location, the Rideau Valley Conservation Authority, South Nation Conservation, Mississippi Valley Conservation or the local municipality. We confirm the correct authority for your address before we design.
1) Site evaluation: test pits, soil analysis and setbacks. 2) Design: drawings and OBC calculations based on bedrooms, fixtures, flow and site limits. 3) Application submitted online, by email or in person. 4) Authority review, typically two to three weeks for a complete package. 5) Installation by a licensed installer. 6) Inspections, after which a Certificate of Completion is issued, usually required before occupancy.
Septic systems must be designed by a qualified professional, such as a BCIN-qualified designer, a Certified Engineering Technologist (C.E.T.) or a Professional Engineer (P.Eng.). Homeowners can design their own only if they hold the appropriate qualification.
Look for BCIN qualification or OACETT/PEO credentials, experience with your local conservation authority and a track record of approved permits. Independence matters too: a designer who doesn't also install has no reason to oversize your system.
A T-time test measures how quickly water moves through your soil. The result tells the designer whether the soil can support a leaching bed and how large the bed needs to be.
We dig test pits, assess the soil profile and T-time, review slopes and grading, and measure setbacks to wells, buildings, watercourses and property lines.
A conventional system is a septic tank plus a leaching bed. A tertiary system adds an advanced treatment unit that cleans effluent further before it reaches the soil, which allows a smaller bed. Tertiary systems are often used on small lots, poor soils or high water tables.
All four are approved advanced treatment technologies, each with a different approach: Ecoflo filters effluent through a coconut-husk media, Waterloo Biofilter uses an absorbent foam media, Norweco uses mechanical aeration and clarification with optional disinfection, and Eljen uses geotextile modules over specified sand. The best fit depends on your site, budget and maintenance preferences.
Class 4 systems (conventional or tertiary), Class 5 holding tanks, and approved treatment units such as Waterloo Biofilter, Norweco, Eljen and Ecoflo, depending on site conditions.
Usually a daily design flow of about 2,400 to 3,000 L/day, depending on fixture count and floor area. Tank size is then calculated from the daily design flow under OBC Table 8.2.1.3.A.
A raised bed or a tertiary treatment system is usually required to achieve proper treatment and separation from groundwater.
A raised bed is a type of mound: the leaching bed is built above original grade, usually because of poor native soil or a high water table.
A compact leaching bed that uses a layer of specified sand to treat effluent. It is used where space is limited and remains fully OBC-compliant.
A mantle is a sand layer extending around and beyond a raised bed or filter bed. It helps disperse treated effluent into the native soil.
A sand manufactured to a strict gradation specification, required for treatment in systems such as Eljen and filter beds. Masonry or beach sand cannot be substituted.
Space set aside on your lot for a future replacement leaching bed, required by the Ontario Building Code in case the original bed eventually fails.
A septic tank treats wastewater and sends effluent to a leaching bed. A holding tank simply stores all wastewater and must be pumped out regularly. Holding tanks are used only where treatment on site is not permitted or not feasible.
Only if a septic system is feasible. That is confirmed through a site evaluation, a T-time test and a design that meets the Ontario Building Code and local requirements.
There is no single provincial minimum. The lot must fit the system, the reserve area and all required setbacks, and some municipalities set their own minimum lot sizes through zoning.
Yes, if the system is sized for the combined daily flow and meets the Building Code. Talk to us and the approval authority before planning a shared system.
Only if it is sized for the extra load. A secondary unit often requires an assessment and may need the system to be expanded and re-permitted, although two units can share one system when the design allows.
Only if the existing system can handle the added daily flow. Extra bedrooms or fixtures often require an upgrade, which a designer can confirm under the Building Code.
Not necessarily, but seasonal use and site access can influence the type of system and the approval process.
Yes. Any dwelling with plumbing needs a septic system or holding tank, unless it uses an approved composting toilet together with approved greywater treatment.
Yes, if they comply with the Ontario Building Code and local health requirements. Greywater from sinks and showers may still need its own treatment system.
The minimum setback from a leaching bed is 15 m to a drilled well and 30 m to a dug or bored well.
Only if Building Code clearances are maintained, generally at least 5 m from the leaching bed (plus twice the raised height of a raised bed) and 1.5 m from the tank. Never build over any part of the system. Have a designer confirm setbacks before you build.
It is not required by law, but it is strongly recommended for any rural real estate transaction. Selling does not automatically require an upgrade, but a failing or non-compliant system may need one.
Every three to five years for most households, depending on household size and water use.
Pump the tank every three to five years, clean the effluent filter annually and schedule periodic inspections. Tertiary systems need regular servicing by an authorized provider.
Only human waste and toilet paper. Keep wipes (even flushable ones), grease, chemicals and medications out of the system, and limit garbage disposal use because it adds solids to the tank.
Yes, but large volumes of brine can affect the system. Some municipalities recommend routing softener discharge away from the tank.
Keep trees and deep-rooted shrubs away from the tank and bed; roots can clog and damage pipes. Shallow-rooted grass is the best cover, and vegetable gardens should not be planted over the bed.
Don't compact snow over the tank or bed, insulate exposed pipes and pump the tank before winter if needed. At seasonal cottages, drain the plumbing lines before closing up.
Yes, especially if it is unused for long periods or poorly insulated. Frozen components need professional thawing.
Slow drains, sewage odours, wet or spongy spots over the bed and sewage backups. Call a licensed professional right away if you notice any of these.
A full tank, a broken pipe, a failing leaching bed or poor venting are the usual causes. Have the system inspected.
Infrequent pumping, grease build-up, tree roots, excessive water use and driving or parking over the bed.
With proper maintenance most systems last 20 to 30 years or more, and the tank often outlasts the leaching bed. Tertiary units need regular servicing to perform as designed.
Check property records or as-built drawings, look for tank lids or inspection ports, or hire a professional with locating equipment.
Some conservation authorities and municipalities offer limited incentives for upgrading failing systems. Check with your local authority for current programs.